Air consumption is an important indicator for evaluating the quality of gas-fired boilers. It is also one of the standards that users measure when purchasing boilers. This data will directly determine the cost of the company's investment in boiler operation.

We use a 1 ton gas-fired steam boiler as the base to calculate the method for calculating the gas consumption of the boiler.

First, factors affecting the gas consumption of the boiler
       1. Boiler heating area
       Generally speaking, the larger the heating area is occupied in the whole boiler, the more heat is transferred to the boiler by the fuel combustion, and the fuel utilization rate is improved. On the one hand, the company saves more fuel.
       2. Fuel calorific value and price
       The calorific value of different types of fuels will also vary. The calorific value of natural gas combustion is 8600 kcal/m3, and the calorific value of diesel is 10240 kcal/kg. However, the cost of fuel should also be considered. comprehensive.
       3. Boiler thermal efficiency
       The thermal efficiency of the boiler is also closely related to the heating area. The larger the heating area, the better the heat transfer effect, which will increase the boiler thermal efficiency linearly, make the fuel utilization more complete, and the gas consumption cost less.
       The condensing gas steam boiler produced by Fangfang uses a advanced condensation technology to set up a condensing recovery device near the flue. When the high-temperature flue gas passes through the device, the latent heat part encounters the condensed water to release heat, which is supplied to the boiler for absorption again. The thermal efficiency can be It is as high as 108%. In one year, it can save the company the fuel input cost of 50,000 to tens of thousands (depending on boiler capacity and maintenance quality).
       4, boiler output
       The output of a 1 ton boiler is 700,000 kcal, and so on. The output of a 10 ton boiler is 7 million kcal.

Second, the fuel consumption calculation formula
       Fuel consumption = boiler output ÷ fuel calorific value ÷ boiler thermal efficiency.

According to the above method, the user can calculate the gas consumption of the gas steam boiler according to the various values ​​provided by the boiler manufacturer, and more comprehensively understand the boiler and select the boiler equipment suitable for the enterprise.

How to calculate the gas consumption of a gas steam boiler?

1. When the gas steam boiler rises from cold ignition to working pressure, the temperature rise and pressure time is generally controlled at 3 to 4 hours. When the boiler pressure rises to 0.05~0.1MPa, the boiler pressure gauge and water level gauge should be flushed; when the boiler pressure rises to 0.15~0.2MPa, the air valve on the boiler should be closed and the safety valve should be checked for leakage. If there is leakage, measures should be taken. When the boiler pressure rises to 0.2~0.25MPa, the boiler shall be subjected to a sewage test. When the sewage is discharged, the boiler water level should be higher than the normal water level, and check whether the sewage valve leaks. If there is leakage, measures should be taken to eliminate it; When the pressure rises to 0.3 MPa, it is necessary to thoroughly inspect the fastening parts of the pressure components of the boiler, such as the manhole, the hand hole, the inspection hole and the bolts connected to the flanges, and perform a hot tightening.

2. The pump can check whether it can maintain the normal water level under the automatic running state. The water level can be started normally below the “starting pump line”, and the water level can stop working in the “stop pump line”.

3. Is the pressure control normal? When the steam pressure reaches the set value, the combustion stops and the overpressure lamp lights up. When the pressure drops to the set value, the boiler can start automatically.

4. When the pressure reaches the load set value, the load is transferred from a large fire to a small fire. When the pressure drops to the set value, it is turned from a small fire to a large fire.

5. When the pressure cannot be stopped under the normal set pressure condition, the second overpressure will alarm and stop the furnace, and must be restarted.

6. The exhaust gas temperature can not exceed 300 ° C, otherwise it should be shut down for inspection.

7. When the gas-fired steam boiler enters the normal operation stage, the boiler boiler personnel should strengthen the monitoring of the boiler body, safety accessories and instruments and auxiliary equipment, and earnestly carry out the patrol inspection of the boiler and auxiliary equipment and fill in the operation record in time.

What problems should be paid attention to when operating a gas steam boiler?

1. Use energy saver and condenser
       The economizer and condenser are mostly installed at the rear of the gas boiler and connected to the flue. When the high-temperature flue gas passes through these two devices, it will release heat due to condensation and be re-supplied to the boiler. The temperature of the flue gas will naturally drop.

2. The use of air preheater
       An air preheater is arranged at the rear pipe of the economizer, and the device can effectively increase the temperature of the combustion air and improve the ignition condition of the fuel. It is very beneficial to the combustion conditions of the boiler.

3. The combustion system adjusts the two-way
       The boiler design specifications have certain adaptability to the fuel. Different media have different effects on the outside during the combustion process. The adjustment is implemented, and the use of economizers and air preheaters is used to control the boiler exhaust gas temperature. The temperature, that is, the full use of thermal energy, can ensure the relative integrity of the structural functions of the equipment, protect the environment, save energy and reduce consumption, and safe development is the social responsibility of all of us.

For an industrial boiler with reasonable structural design, its thermal efficiency is relatively high, and its exhaust gas discharge temperature is relatively low, so we must carefully consider the boiler property report form when purchasing the boiler.

How to reduce the exhaust gas temperature of gas boilers?